Web Data Loggers
Web-enabled Remote Terminal Unit

- DL8 Series
 Web Enabled Remote Terminal Unit Use internet and your own smart phone to build up remote monitoring system - Functions & Features  - Simple remote monitoring via internet without needing to build up a complex PC based system  - Pre-installed user-friendly browser view for remote data access through smart phones or tablets  - Reporting by e-mails  - Local data stored in an SD card memory  - Various network protocols are usable: TCP/IP, SMTP client, HTTP server, FTP client and server, Modbus/TCP master and slave  - R8 Series remote I/O modules available to accept a wide variety of field signals - ● M-System Company does not provide smart phones and/or telecommunication services. - Model - Features - CE marking - DL8-A - Web server - Yes - DL8-B - Web server + E-mailing - Yes - DL8-C - Web server + E-mailing + SD card logging - Yes - DL8-D - Web server + E-mailing + SD card logging 
 + I/O mapping + User-defined browser view- Yes - DL8 Series System Concept - M-System's model DL8 is a remote terminal unit with basic web server function. Various sensor signals are gathered from built-in I/O modules or remote I/Os connected through Ethernet Modbus/TCP, and monitored through Intranet or Internet using a web browser.  - Web Browser Views - Users do not need any additional application program to view the data. User-friendly browser views are already installed: Data, Trend and Event Log views. Each one is basic but useful, designed for ease of browsing on a small screen of smart phones and tablets.  
- DL8 Series Components - RTU MODULE - Featured Functions - Model - Browse - --- - --- - --- - DL8-A - Browse - Report - --- - --- - DL8-B - Browse - Report - Log - --- - DL8-C - Browse - Report - Log - I/O mapping 
 User defined browser view- DL8-D - I/O MODULE I/O Module TypeModel- DC current input (2 points, isolated) - R8-SS2 - DC current input (4 points, non-isolated) - R8-SS4N - DC voltage input (2 points, isolated) - R8-SV2 - DC voltage input (4 points, non-isolated) - R8-SV4N - RTD input (4 points, non-isolated) - R8-RS4N - Contact input (4 points, NPN) - R8-DA4A - Contact input (16 points, NPN) - R8-DAM16A - Totalized pulse input (4 points, NPN/PNP/voltage pulse) - R8-PA4 - Transistor output (4 points, NPN, shortcircuit protection) - R8-DC4A - Transistor output (16 points, NPN, shortcircuit protection) - R8-DCM16A 
- DL8 Series Functions- Data can be uploaded to a cloud server or a PC by FTP, so that multiple users can access it at once without overloading the local DL8 module. Local data logging in CSV format is available by using an SD card memory, thus the DL8 functioning as a stand-alone data logger. - Each signal channel is available with alarm threshold setting to trip alarm contact outputs by adding discrete output modules for buzzers and lamps. E-mailing with a preset message attached with event data is also possible. Mails can be used for regular reporting purposes, too. - At the maximum of 32 analog signals, 64 each of discrete inputs and outputs, and 32 pulse signals can be handled by one DL8 module. M-System's remote I/O model R7E, R3-NE1 and other Modbus/TCP slaves can be connected. Modbus RTU devices such as Multi Power Monitor L53U are connected through a gateway unit (model: 72EM2). I/O data is assigned by using only general address information (IP address, node number and channel), so that other manufacturers' I/Os are also usable. - The DL8 functions as Modbus master to collect data from remote I/O, while it functions as Modbus slave when a supervisory monitoring system (SCADA) polls data of the DL8.  TypeFunctionsDescriptions TypeFunctionsDescriptions- Browse  - I/O signal status in the DL8 web server can be directly monitored with an internet browser.  - The DL8, operating as FTP client, uploads web use files to a cloud server. 
 Multiple users can access it at once without extra load at the DL8. - I/Os located within 500-meter distance can be collected and accessed via single DL8 module. - Report  - Events can be reported by texting. 
 Regular reporting and test mailing are also possible. - Event can trigger an alarm contact at a discrete output module.  - Specific data can be converted into user defined CSV files and uploaded to an FTP server. - Log  - Data is sampled and stored in CSV format in an SD card.  - The host supervising system (PC) can upload CSV data files from the DL8, operating as FTP server. 
- DL8 Series Setup- Network, I/O, web server, mail, FTP, logging and other parameters are set up by using the PC Configurator Software model DLCFG, connected either locally via a special cable (models: MCN-CON or COP-US) or remotely via network. - Setup Items - How to Setup 
- DL8 Series Network System Configurations 
- DL8 Series Specifications (model: DL8-C) 
- DL8 Series Application ExamplesFieldsApplicable AreaApplication- Gas Filling Station - Public utility, infrastructure - Remote monitoring system for CNG gas filling stations - Irrigation Canal Gate - Public utility, infrastructure - Remote control of an irrigation canal gate - Boiler - Machinery & equipment - Test run monitoring of a boiler - Greenhouse - Agriculture, livestock raising - Remote monitoring of greenhouses - Gas Cogeneration Generator - Electricity, gas - Monitoring of gas cogeneration generators - Manhole Pump - Water and sewerage - Remote monitoring of manhole pumps - Water Quality Analyzer - Water and sewerage - Remote monitoring of water quality analyzers - Microbrewery - Factory production lines - Monitoring of carbon dioxide concentration, etc., 
 in fermentation and maturation processes- Warehouse - Logistics - Remote monitoring of temperature and humidity in rice storage warehouses - Cleanroom - Equipment / Machines - Monitoring of air supply and ventilation volume to cleanrooms, external atmospheric pressure - Weather Observation Data - Public / Daily life - Remote monitoring of weather observation data - Enlarged view  - Enlarged view  - Enlarged view  - Enlarged view   


 
  
 