- Application- Display for digital readout of current / voltage / resistance / temperature or potentiometer signals.
- Process control with 2 potential-free relays and / or analog output.
- For local readout in extremely wet atmospheres with a specially designed splash-proof cover.
 - Technical characteristics- 4-digit LED indicator with 13.8 mm 14-segment characters. Max. display readout -1999...9999 with programmable decimal point and relay ON / OFF indication.
- All standard operational parameters can be adjusted to any application by way of the front function keys.
- Help texts in eight languages can be selected via a menu item.
- PR5714 is available fully-configured according to specifications ready for process control and visualization.
- In versions with relay outputs the user can minimize the installation test time by activating / deactivating each relay independently of the input signal.
 - Mounting / installation- To be mounted in panel front. The included rubber packing must be mounted between the panel cutout hole and the display front to obtain a protection degree of IP65 (type 4X). For extra protection in extreme environments, PR5714 can be delivered with a specially designed splash-proof cover as accessory.
 
- Environmental Conditions- Specifications range - -20°C to +60°C - Calibration temperature - 20...28°C - Relative humidity - < 95% RH (non-cond.) - Protection degree (mounted in panel) - IP65 / Type 4X, UL50E - Mechanical specifications- Dimensions (HxWxD) - 48 x 96 x 120 mm - Cut out dimensions - 44.5 x 91.5 mm - Weight approx. - 230 g - Wire size, pin 41-46 (max.) - 1 x 1.5 mm2 stranded wire - Wire size, others, max. - 1 x 2.5 mm2 stranded wire - Vibration - IEC 60068-2-6 : 2007 - Vibration: 2...25 Hz - ±1.6 mm - Vibration: 25...100 Hz - ±4 g - Common specifications- Supply voltage, universal - 21.6...253 VAC, 50...60 Hz or 19.2...300 VDC - Max. power consumption - 2.5 W (5714A) 3.0 W (5714B/C) 
 3.5 W (5714D)- Internal consumption - 2.2 W (5714A) 2.7 W (5714B/C) 
 3.2 W (5714D)- Isolation voltage, test / working - 2.3 kVAC / 250 VAC - Signal / noise ratio - Min. 60 dB (0...100 kHz) - Accuracy - Better than 0.1% of selected range - Response time (0...90%, 100...10%): Temperature input (programmable) - 1...60 s - mA / V input (programmable) - 0.4...60 s - Auxiliary supply: 2-wire supply (pin 46...45) - 25...15 VDC / 0...20 mA - EMC immunity influence - < ±0.5% of readout - Input specifications- RTD input - Pt10, Pt20, Pt50, Pt100, Pt200, Pt250, Pt300, Pt400, Pt500, Pt1000 Ni50, Ni100, Ni120, Ni1000, Cu10, Cu20, Cu50, Cu100 Linear resistance 
 Potentiometer- Cable resistance per wire (max.), RTD - 50 Ω - Sensor current, RTD - Nom. 0.2 mA - Effect of sensor cable resistance (3-/4-wire), RTD - < 0.002 Ω / Ω - Sensor error detection, RTD - Yes - Short circuit detection, RTD - < 15 Ω - TC input: Thermocouple type - B, E, J, K, L, N, R, S, T, U, W3, W5, LR - CJC via internally mounted sensor - ±(2.0°C + 0.4°C * Δt) - Δt = - Internal temperature-ambient temperature - Sensor error detection, TC - Yes - Sensor error current: When detecting / else - Nom. 2 μA / 0 μA - Current input: Measurement range - 0...20 mA - Current input: Programmable measurement ranges - 0...20 and 4...20 mA - Input resistance, current input - Nom. 20 Ω + PTC 25 Ω - Sensor error detection, current input - Loop break 4...20 mA - Voltage input: Measurement range - 0...12 VDC - Programmable measurement ranges, VDC - 0/0.2...1; 0/2...10 VDC - Input resistance, voltage input - Nom. 10 MΩ - Output specifications- Display readout - -1999...9999 (4 digits) - Decimal point - Programmable - Digit height - 13.8 mm - Display updating. - 2.2 times / s - Input outside input range is indicated by - Explanatory text - Current output: Signal range - 0...20 mA - Programmable current ranges - 0...20 / 4...20 / 20...0 and 20...4 mA - Load (max.) - 20 mA/800 Ω/16 VDC - Load stability, current output - ≤0.01% of span / 100 Ω - Sensor error indication, current output - 0 / 3.5 / 23 mA / none - NAMUR NE 43 Upscale/Downscale - 23 mA / 3.5 mA - Output limitation, on 4...20 and 20...4 mA signals - 3.8...20.5 mA - Output limitation, on 0...20 and 20...0 mA signals - 0...20.5 mA - Current limit - ≤ 28 mA - Relay output: Relay functions - Setpoint - Hysteresis - 0...100% - ON and OFF delay - 0...3600 s - Sensor error reaction - Break / Make / Hold - Max. voltage - 250 VRMS - Max. current - 2 AAC - Max. AC power - 500 VA - Max. load at 24 VDC - 1 A - Approvals- EMC - EN 61326-1 - LVD 2006/95/EC - EN 61010-1 - EAC TR-CU 020/2011 - EN 61326-1 - DNV Marine - Stand. f. Certific. No. 2.4 - UL - UL 508 


 
  
 