- Application- Power supply and signal isolator for 2-wire transmitters.
- Signal isolator for analog current / voltage signals.
- 1 : 1 or signal conversion of analog current / voltage signals.
 - Technical characteristics- The 20 factory-calibrated measurement ranges in the 5104A can be selected by the internal DIP-switches without the need for recalibration. Special measurement ranges can be delivered.
- PR5104A is based on microprocessor technology for gain and offset. The analog signal is transmitted at a response time of less than 25 ms.
- Inputs, outputs, and supply are floating and galvanically separated.
- The output can be connected either as an active current / voltage transmitter or as a 2-wire transmitter.
 - Mounting / installation- Mounted vertically or horizontally on a DIN rail. By way of the 2-channel version up to 84 channels per meter can be mounted.
 
- Environmental Conditions- Specifications range - -20°C to +60°C - Calibration temperature - 20...28°C - Relative humidity - < 95% RH (non-cond.) - Protection degree - IP20 - Mechanical specifications- Dimensions (HxWxD) - 109 x 23.5 x 130 mm - Weight approx. - 225 g - DIN rail type - DIN 46277 - Wire size - 1 x 2.5 mm2 stranded wire - Screw terminal torque - 0.5 Nm - Common specifications- Supply voltage, universal - 21.6...253 VAC, 50...60 Hz or 19.2...300 VDC - Fuse - 400 mA SB / 250 VAC - Max. power consumption - ≤ 3 W (2 channels) - Internal consumption - ≤ 2 W (2 channels) - Isolation voltage, test / working - 3.75 kVAC / 250 VAC - Signal / noise ratio - Min. 60 dB (0...100 kHz) - Response time (0...90%, 100...10%) - < 25 ms - Auxiliary supply: 2-wire supply (pin 44...42 and 54...52) - 28...17.1 VDC / 0...20 mA - EMC immunity influence - < ±0.5% of span - Extended EMC immunity: NAMUR NE 21, A criterion, burst - < ±1% of span - Input specifications- Max. offset - 20% of max. value - Current input: Measurement range - 0...20 mA - Min. measurement range (span), current input - 16 mA - Input resistance, current input - Nom. 10 Ω + PTC 10 Ω - Voltage input: Measurement range - 0...10 VDC - Min. measurement range (span), voltage input - 8 VDC - Input resistance, voltage input - > 2 MΩ - Output specifications- Max. offset - 20% of max. value - Current output: Signal range - 0...20 mA - Min. signal range - 16 mA - Load (max.) - 20 mA/600 Ω/12 VDC - Load stability, current output - ≤0.01% of span / 100 Ω - Current limit - ≤ 28 mA - Max. external 2-wire supply - 29 VDC - Effect of external 2-wire supply voltage variation - < 0.005% of span / V - Voltage output: signal range - 0...1 VDC / 0...10 VDC - Voltage output, min. signal range - 0.8 VDC / 8 VDC - Load (min.) - 500 kΩ - *of span - = of the presently selected range - Approvals- EMC - EN 61326-1 - LVD 2006/95/EC - EN 61010-1 - PELV/SELV - IEC 364-4-41 and EN 60742 - UL - UL 508 - EAC TR-CU 020/2011 - EN 61326-1 - DNV Marine - Stand. f. Certific. No. 2.4 


 
  
 