- Advanced features- Configuration and monitoring by way of detachable display front (PR 4511/4501); process calibration, signal and relay simulation.
- Advanced relay configuration, e.g. setpoint, window, delay, sensor error indication and power monitoring.
- Copying of the configuration from one device to others of the same type via the display front.
- TC inputs with internal CJC or external CJC for higher accuracy.
- The device automatically detects whether it must supply an active or a passive current signal.
 - Application- The device can be mounted in and receive signals from non-classified area and zone 2.
- Conversion and scaling of temperature, voltage, potentiometer and linear resistance signals.
- Power supply and signal isolator for 2-wire transmitters.
- Monitoring of error events and cable breakage via the individual status relay and/or a collective electronic signal via the power rail.
- 9116A has been designed, developed and certified for use in SIL 2 applications according to the requirements of IEC 61508.
 - Technical characteristics- 1 green and 1 red front LED indicate operation status and malfunction. 1 yellow LED indicates relay status.
- 2.6 kVAC galvanic isolation between input, output and supply.
 - Mounting- The devices can be mounted vertically or horizontally without distance between neighbouring units.
 
- Environmental Conditions- Specifications range - -20°C to +60°C - Storage temperature - -20°C to +85°C - Calibration temperature - 20...28°C - Relative humidity - < 95% RH (non-cond.) - Protection degree - IP20 - Installation in - Pollution degree 2 & measurement / overvoltage cat. II - Mechanical specifications- Dimensions (HxWxD) - 109 x 23.5 x 104 mm - Dimensions (HxWxD) w/ 4501 / 4511 - 109 x 23.5 x 116 / 131 mm - Weight approx. - 185 g - Weight incl. 4501 / 4511 (approx.) - 200 g / 285 g - DIN rail type - DIN EN 60715/35 mm - Wire size - 0.13...2.08 mm2AWG 26...14 stranded wire - Screw terminal torque - 0.5 Nm - Vibration - IEC 60068-2-6 : 2007 - Vibration: 2...13.2 Hz - ±1 mm - Vibration: 13.2...100 Hz - ±0.7 g - Common specifications- Supply voltage - 19.2...31.2 VDC - Fuse - 1.25 A SB / 250 VAC - Max. power consumption - ≤ 3.5 W - Isolation voltage, test /working: Input to any - 2.6 kVAC / 300 VAC reinforced isolation - Analog output to supply - 2.6 kVAC / 300 VAC reinforced isolation - Status relay to supply - 1.5 kVAC / 150 VAC reinforced isolation - Communications interface - Communication enabler 4511 / Programming front 4501 - Signal / noise ratio - Min. 60 dB (0...100 kHz) - Response time (0...90%, 100...10%): Temperature input (programmable) - 1...60 s - mA / V input (programmable) - 0.4...60 s - Accuracy - Better than 0.1% of selected range - Auxiliary supplies for 9116B1: 2-wire supply (terminal 54...52) - 28...16.5 VDC / 0...20 mA - Auxiliary supplies for 9116B2: 2-wire supply (terminal 54...52) - 22...16.5 VDC / 0...20 mA - Input specifications- RTD input - Pt10, Pt20, Pt50, Pt100, Pt200, Pt250, Pt300, Pt400, Pt500, Pt1000, Ni50, Ni100, Ni120, Ni1000 - Cable resistance per wire (max.), RTD - 50 Ω - Sensor current, RTD - Nom. 0.2 mA - Effect of sensor cable resistance (3-/4-wire), RTD - < 0.002 Ω / Ω - Sensor error detection, RTD - Programmable ON / OFF - Short circuit detection, RTD - Yes - TC input: Thermocouple type - B, E, J, K, L, N, R, S, T, U, W3, W5, LR - Cold junction compensation (CJC) via ext. sensor in connector 5910 - 20...28°C ≤ ±1°C, -20...20°C / 28...70°C ≤ 2°C - CJC via internally mounted sensor - ±(2.0°C + 0.4°C * Δt) - Δt = - Internal temperature-ambient temperature - Sensor error detection, TC - Programmable ON or OFF (only wire breakage) - Current input: Measurement range - 0...20 mA - Current input: Programmable measurement ranges - 0...20 and 4...20 mA - Input resistance, current input - Nom. 20 Ω + PTC 50 Ω - Sensor error detection, current input - Loop break 4...20 mA - Voltage input: Measurement range - 0...10 VDC - Programmable measurement ranges, VDC - 0/0.2...1, 0/1...5, 0/2...10 VDC - Input resistance, voltage input - Nom. >10 MΩ - Output specifications- Current output: Signal range - 0...20 mA - Programmable current ranges - 0...20 / 4...20 / 20...0 and 20...4 mA - Load (max.) - 20 mA/600 Ω/12 VDC - Load stability, current output - ≤0.01% of span / 100 Ω - Sensor error indication, current output - 0 / 3.5 / 23 mA / none - NAMUR NE 43 Upscale/Downscale - 23 mA / 3.5 mA - Output limitation, on 4...20 and 20...4 mA signals - 3.8...20.5 mA - Output limitation, on 0...20 and 20...0 mA signals - 0...20.5 mA - Current limit - ≤ 28 mA - 2-wire 4…20 mA output: External 2-wire supply range - 3.5...26 VDC - Signal range - 4…20 mA - Max. load resistance [Ω] - (Vsupply - 3.5) / 0.023 A - Load stability, 4…20 mA output - ≤ 0.01% of span / 100 Ω - Effect of external 2-wire supply voltage variation - < 0.005% of span / V - Relay output: Relay functions - Setpoint, Window, Sensor error, Power and Off - Hysteresis, in % of span/display range - 0.1...25 / 1...25 - ON and OFF delay - 0...3600 s - Sensor error reaction - Break / Make / Hold - Max. voltage - 250 VAC / 30 VDC - Max. current - 2 AAC / 2 ADC - Max. AC power - 500 VA / 60 W - Max. voltage, status relay - 110 VDC / 125 VAC - Max. current, status relay - 0.3 ADC / 0.5 AAC - Max. AC power, status relay - 62.5 VA / 32 W - *of span - = of the currently selected measurement range - Approvals- EMC - EN 61326-1 - LVD 2006/95/EC - EN 61010-1 - UL - UL 61010-1 - DNV Marine - Stand. f. Certific. No. 2.4 - SIL - SIL 2 certified & fully assessed acc. to IEC 61508 


 
  
 