- Advanced features- The front-operated push buttons are used for programming the different standard functions.
- A password can prevent access for changing parameters.
 - Application- Alarm detector in connection with measurement of AC/DC current or voltage signals.
- The unit is used where accurate setpoint setting and different alarm functions are required.
- The unit can be used as a single or dual trip amplifier.
- Used in applications where programmable parameters such as hysteresis, setpoint, reset, active relay for increasing or decreasing signal, delay and input signal need to be set.
 - Technical characteristics- 3-digit display showing the input signal in %.
- Two LED indicating relay status.
- 3 pushbuttons for programming.
- Standard DC current input signals in the range 0...20 mA.
- DC voltage signals in the range 0...250 VDC.
- AC current signals up to 1 A.
- True RMS measurement of AC voltage signals in the range 0...250 VAC.
- Mounting for a standard 11-pole socket which can be adapted for DIN rail or plate use with PR’s 7023 adaptor and 7024 mounting keying.
 
- Environmental Conditions- Specifications range - -20°C to +60°C - Calibration temperature - 20...28°C - Relative humidity - < 95% RH (non-cond.) - Protection degree - IP50 - Mechanical specifications- Dimensions (HxWxD) - 80.5 x 35.5 x 84.5 mm (D is without pins) - Weight DC / universally supplied - 125 g / 175 g - Common specifications- Supply voltage - 19.2...28.8 VDC - Supply voltage, universal - 21.6...253 VAC, 50...60 Hz or 19.2...300 VDC - Internal consumption - 1.5 W (2231D) 2 W (2231P) - Isolation voltage, test / working - 3.75 kVAC / 250 VAC - Response time (programmable) - 0.25...60 s (DC) 0.75...60 s (AC) - Updating time - 100 ms - Accuracy - Better than 0.1% of selected range - Signal dynamics, input - 16 bit - Effect of supply voltage change - < ±0.002% of span / %V - Temperature coefficient - < ±0.01% of span /°C (DC signals) < ±0.02% of span /°C (AC signals) - Linearity error - < 0.1% of span < ±0.35% of span 50...1000 Hz (AC sine wave signals) - EMC immunity influence - < ±0.5% - Input specifications- Max. offset - 50% of selected max. value - Current input: Measurement range - 0...20 mA - Min. measurement range (span), current input - 10 mA - Input resistance, current input - 50 Ω - AC current input: Measurement range - 0...1 ARMS - Min. measurement range (span), AC current - 0.5 ARMS - Input resistance, AC current - 1 Ω / 2 W - Voltage input: Measurement range - 0...250 VDC - Min. measurement range (span), voltage input - 0.5 VDC - Input resistance, voltage input - Nom. 5 MΩ - AC voltage input: Measurement range - 0...250 VRMS - Min. measurement range (span), AC voltage - 0.5 VRMS - Input resistance, AC voltage - Nom. 5 MΩ - Output specifications- Relay outputs: Setpoint setting - 0...99.9% of span - Hysteresis - 0...99.9% of span - Updating time - 100 ms - ON and OFF delay - 0.0...99.9 s - Max. voltage - 250 VRMS - Max. current - 2 AAC - Max. AC power - 500 VA - Max. load at 24 VDC - 1 A - *of span - = of the presently selected range - Approvals- EMC - EN 61326-1 - LVD 2006/95/EC - EN 61010-1 - PELV/SELV - IEC 364-4-41 and EN 60742 - EAC TR-CU 020/2011 - EN 61326-1 


 
  
 