- Advanced features- A multifunction user interface consisting of three pushbuttons and a 3-digit LED display for programming.
 - Application- The 2261 converts bipolar mV signals from transducers supplied directly by the device to standard current / voltage signals.
- The 2261 is suitable for load cell application as well as other applications such as tank filling and draining, weighing with a taring function, measurement of cable tensile force, level control, signal conversion / amplification etc.
 - Technical characteristics- Front error LED.
- The analog input can be programmed for voltage in the range -40...100 mVDC.
- The digital signal can be selected as either NPN or PNP.
- Taring can either be by way of the digital input or from the front interface.
- The analog output can be programmed to current in the range 0...20 mA or voltage in the range 0...10 VDC.
- Short circuit protected transducer supply which can be programmed to 5...13 VDC from the front.
- Sense input (with transducer supply used) for compensation for cable resistance to the transducer.
- Mounting for a standard 11-pole socket which can be adapted for DIN rail or plate use with PR’s 7023 adaptor and 7024 mounting keying.
 
- Environmental Conditions- Specifications range - -20°C to +60°C - Calibration temperature - 20...28°C - Relative humidity - < 95% RH (non-cond.) - Protection degree - IP50 - Mechanical specifications- Dimensions (HxWxD) - 80.5 x 35.5 x 84.5 mm (D is without pins) - Weight approx. - 130 g - Common specifications- Supply voltage - 19.2...28.8 VDC - Max. power consumption - 7.2 W - Internal consumption - 2.2 W - Signal / noise ratio - Min. 60 dB - Response time (programmable) - 0.06...999 s - Updating time - 20 ms - Signal dynamics, input - 17 bit - Signal dynamics, output - 16 bit - Effect of supply voltage change - < ±0.002% of span / %V - Temperature coefficient - < ±0.01% of span / °C - Linearity error - < 0.1% of span - Auxiliary voltage: Transducer supply - 5...13 VDC - Load (max.) - 230 mA - EMC immunity influence - < ±0.5% of span - Input specifications- Max. offset - 70% of selec. max. value - Voltage input: Measurement range - -40...100 mV - Min. measurement range (span), voltage input - 10 mV - Input resistance, voltage input - > 10 MΩ - Overrange - 0...999% of selected measurement range - NPN, digital input - Pull up 24 VDC / 6.9 mA - PNP, digital input - Pull down 0 VDC / 6.9 mA - Trig level low, NPN/PNP - < 6 VDC - Trig level high, NPN/PNP - > 10.5 VDC - Pulse length - > 30 ms - Output specifications- Max. offset - 50% of selected max. value - Current output: Signal range - 0...20 mA - Min. signal range - 5 mA - Load (max.) - 20 mA/600 Ω/12 VDC - Load stability, current output - ≤0.01% of span / 100 Ω - Current limit - < 23 mA - Voltage output through internal shunt - See manual for details - *of span - = of the presently selected range - Approvals- EMC - EN 61326-1 - EAC TR-CU 020/2011 - EN 61326-1 


 
  
 