- Application- Conversion of resistance variation to standard analog current signals, e.g. from Ohmic level sensors or valve positions.
- User-defined linearization function can be activated.
 - Technical characteristics- Within a few seconds the user can program PR5343A to measure within the defined Ohmic values.
- Continuous check of vital stored data for safety reasons.
- The transmitter is protected against polarity reversal.
- PR5343A is configured to the current task by way of a PC, the PReset software and the communications interface Loop Link.
- The PRelevel configuration tool included in the PReset software has been developed specifically for the configuration of level applications. Among other things, it contains a function for ”on line” measurement of input span as well as a linearization function for volume linear output from horizontal cylindrical tanks.
 - Mounting / installation- For DIN form B sensor head or DIN rail mounting with a special fitting.
 
- Environmental Conditions- Specifications range - -40°C to +85°C - Calibration temperature - 20...28°C - Relative humidity - < 95% RH (non-cond.) - Protection degree (encl./terminal) - IP68 / IP00 - Mechanical specifications- Dimensions - Ø 44 x 20.2 mm - Weight approx. - 50 g - Wire size - 1 x 1.5 mm2 stranded wire - Screw terminal torque - 0.4 Nm - Vibration - IEC 60068-2-6 : 2007 - Vibration: 2...25 Hz - ±1.6 mm - Vibration: 25...100 Hz - ±4 g - Common specifications- Supply voltage - 8.0...35 VDC - Internal consumption - 25 mW…0.8 W - Voltage drop - 8.0 VDC - Warm-up time - 5 min. - Communications interface - Loop Link - Signal / noise ratio - Min. 60 dB - Accuracy - Better than 0.1% of selected range - Response time (programmable) - 0.33...60 s - Signal dynamics, input - 19 bit - Signal dynamics, output - 16 bit - Effect of supply voltage change - < 0.005% of span / VDC - EMC immunity influence - < ±0.5% of span - Input specifications- Max. offset - 50% of selected max. value - Linear resistance input: Measurement range / min. range (span) - 0...100 kΩ / 1 kΩ - Min. measurement range - 1 kΩ - Cable resistance per wire (max.), lin. R - 100 Ω - Sensor current, lin. R - > 25 μA, < 120 μA - Effect of sensor cable resistance (3-wire), lin R. - < 0.002 Ω / Ω - Sensor error detection, lin. R - Yes - Output specifications- Current output: Signal range - 4…20 mA - Min. signal range - 16 mA - Updating time - 135 ms - Load resistance, current output - ≤ (Vsupply - 8) / 0.023 [Ω] - Load stability, current output - ≤0.01% of span / 100 Ω - Sensor error indication, current output - Programmable 3.5…23 mA - NAMUR NE 43 Upscale/Downscale - 23 mA / 3.5 mA - *of span - = of the presently selected range - Approvals- EMC - EN 61326-1 - ATEX 2004/108/EC - KEMA 10ATEX0004 X - IECEx - DEK 13.0036X - INMETRO - DEKRA 13.0002 X - EAC TR-CU 020/2011 - EN 61326-1 - DNV Marine - Stand. f. Certific. No. 2.4 - GL - V1-7-2 


 
  
 