- Advanced features- 0 and 100% adjustments on the front face can be adjusted individually without interacting.
 - Application- Linearized temperature measurement with Pt100 (to IEC 751) or Ni100 (to DIN 43760) sensors.
- Conversion of linear resistance change to standard analog current/voltage signal from for example valves or linear movements with attached potentiometer.
- Signal simulator via externally mounted 10-turn potentiometer, to aid with installation and commissioning plant.
- 3-wire connection cable compensation or 2-wire connection without cable compensation.
- Sensor error detection with Upscale, Downscale or custom set values.
- Reversible inputs with 0% set to maximum value of the desired input range and 100% set to the minimum value of the desired input range.
 - Technical characteristics- Analog current and voltage output options include 0/4...20 mA, 0/2...10 VDC and special ranges.
- Galvanic isolation between supply and input / output ground.
- Mounting for a standard 11-pole socket which can be adapted for DIN rail or plate use with PR’s 7023 adaptor and 7024 mounting keying.
 
- Environmental Conditions- Specifications range - -20°C to +60°C - Calibration temperature - 20...28°C - Relative humidity - < 95% RH (non-cond.) - Protection degree - IP50 - Mechanical specifications- Dimensions (HxWxD) - 80.5 x 35.5 x 84.5 mm (D is without pins) - Weight DC / universally supplied - 100 g / 150 g - Common specifications- Supply voltage - 19.2...28.8 VDC - Supply voltage, universal - 21.6...253 VAC, 50...60 Hz or 19.2...300 VDC - Internal consumption - ≤ 0.9 W (2202 _ _ D) ≤ 1.4 W (2202 _ _ P) - Isolation voltage, test / working - 3.75 kVAC / 250 VAC - Accuracy - Better than 0.1% of selected range - Signal / noise ratio - Min. 60 dB - Signal dynamics, input - 17 bit - Response time (0...90%, 100...10%) - < 165 ms - Signal dynamics, output - 16 bit - Temperature coefficient - ±0.01°C/°Camb. (span < 100°C) ±0.01% of span/°Camb. (span > 100°C) - Linearity error - < 0.1% of span - EMC immunity influence - < ±0.5% - Input specifications- Max. offset - 50% of max. value - Adjustment acc. to order - ±2.5...±25% of span - RTD input - Pt100, Ni100, lin. R - Cable resistance per wire (max.), RTD - 10 Ω - Sensor current, RTD - > 0.2 mA, < 0.4 mA - Output specifications- Max. offset - 50% of max. value - Current output: Signal range - 0...20 mA - Min. signal range - 5 mA - Load (max.) - 20 mA/600 Ω/12 VDC - Load stability, current output - ≤0.01% of span / 100 Ω - Sensor error indication, current output - Upscale / Downscale - Current limit - ≤ 28 mA - Voltage output: signal range - 0...10 VDC - Voltage output, min. signal range - 250 mV - *of span - = of the presently selected range - Approvals- EMC - EN 61326-1 - EAC TR-CU 020/2011 - EN 61326-1 


 
  
 