- Application- The 3111 temperature converter measures standard TC J and K temperature sensors, and provides an isolated analog voltage or current output.
- High 3 port isolation provides surge suppression and protects the control system from transients and noise.
- The 3111 can be mounted in the safe area or in Zone 2 / Division 2 areas.
- Approved for marine applications.
 - Technical characteristics- Flexibly powered by 24 VDC (±30%) via power rail or connectors.
- < 30 ms fast response time with simultaneous sensor error detection when selected.
- Selectable 300 ms response time when signal dampening is needed.
- Selectable internal/external CJC.
- Excellent conversion accuracy in all available ranges, better than 0.05% of span.
- Meeting the NAMUR NE21 recommendations, the 3111 provides top measurement performance in harsh EMC environments.
- The device meets the NAMUR NE43 standard defining out of range and sensor error output values.
- A visible green LED indicates operational status of the unit and the input sensor.
- All terminals are protected against overvoltage and polarity error.
- High galvanic isolation of 2.5 kVAC.
- Excellent signal/noise ratio of > 60 dB.
 - Mounting / installation / programming- Selectable DIP-settings for easy configuration of more than 1000 factory calibrated measurement ranges.
- The narrow 6 mm housing allows up to 165 units to be mounted per meter of DIN rail, without any air gap between units.
- Wide ambient temperature range of -25...+70°C.
 
- Environmental Conditions- Specifications range - -25°C to +70°C - Storage temperature - -40°C to +85°C - Calibration temperature - 20...28°C - Relative humidity - < 95% RH (non-cond.) - Protection degree - IP20 - Installation in - Pollution degree 2 & measurement / overvoltage cat. II - Mechanical specifications- Dimensions (HxWxD) - 113 x 6.1 x 115 mm - Weight approx. - 70 g - DIN rail type - DIN EN 60715/35 mm - Wire size - 0.13 x 2.5 mm2 / AWG 26...12 stranded wire - Screw terminal torque - 0.5 Nm - Vibration - IEC 60068-2-6 : 2007 - Vibration: 2...25 Hz - ±1.6 mm - Vibration: 25...100 Hz - ±4 g - Common specifications- Supply voltage - 16.8...31.2 VDC - Max. power consumption - 0.7 W - Isolation voltage, test - 2.5 kVAC - Isolation voltage, working - 300 VAC (reinforced) / 250 VAC (Zone 2, Div. 2) - Signal / noise ratio - > 60 dB - Signal dynamics, input - 23 bit - Signal dynamics, output - 18 bit - Response time (0...90%, 100...10%) - < 30 ms / 300 ms (selectable) - Accuracy - Better than 0.05% of selected range - EMC immunity influence - < ±0.5% of span - Extended EMC immunity: NAMUR NE 21, A criterion, burst - < ±1% of span - Incorrect DIP-switch setting identification - 0 V / 0 mA output; LED 0.5 s / 1 Hz - Input specifications- Temperature range, TC J - -100...+1200°C - Temperature range, TC K - -180...+1372°C - Accuracy, TC: the greater of - Better than 0.05% of span or 0.5°C - Temperature coefficient, TC: the greater of - 0.1°C/°C or ≤ ±0.01%/°C - Sensor cable resistance, TC - < 5 kΩ per wire - Cold junction compensation (CJC): Accuracy @ external Pt100 intput - Better than ±0.15°C - Cold junction compensation (CJC): Accuracy @ internal CJC - Better than ±2.5°C - Open Thermocouple detection - Yes - selectable via DIP-switch - Internal CJC error detection - Yes - External CJC error detection - Yes - selectable via DIP-switch - Output specifications- Programmable current ranges - 0 / 4...20 mA - Range limits (0...20 mA) - 0...20.5 mA - Sensor error indication (0...20 mA) - 0 mA or 23 mA / OFF - Range limits (4...20 mA) - 3.8...20.5 mA acc. to NAMUR NE43 - Sensor error indication (4...20 mA) - 3.5 mA or 23 mA / acc. to NAMUR NE43 or OFF - Load (@ current output) - ≤ 600 Ω (12.6 V / 21 mA) - Open output - < 18 V - Updating time - 10 ms - Load stability, current output - ≤0.01% of span / 100 Ω - Programmable voltage ranges - 0/1...5 and 0/2...10 V - Low range - 0/1...5 V - Limits, low range - 0/0.875...5.125 V - High range - 0/2...10 V - Limits, high range - 0/1.75...10.25 V - Sensor error indication, voltage output - 0 V / 10% above the max. / none - Load (@ voltage output) - ≥ 10 kΩ - Current limitation @ low output load - < 60 mA peak / < 4 mA average - Approvals- EMC - EN 61326-1 - LVD 2006/95/EC - EN 61010-1 - ATEX 2004/108/EC - KEMA 10ATEX0147 X - IECEx - KEM 10.0068X - FM - 3041043-C - DNV Marine - Stand. f. Certific. No. 2.4 - GL - V1-7-2 - EAC TR-CU 020/2011 - EN 61326-1 - UL - UL 61010-1 


 
  
 